Mouse over image to zoom
LIFT-PUMPING MODULES COMPLIANT WITH EN 12050 - 1 / EN 12050 - 2 STANDARD
Collection and lift-pumping of wastewater from collective residential, tertiary and commercial buildings.
TECHNICAL SPECIFICATIONS
Flow rates of up to : 62 m³/h
Manometric head of up to: : 25 mWC
Fluid temperature limit : +35°C
Starting frequency : Recommended: 20/h
Maximum particle size : 10 to 44 mm
Effluent inlet : DN 100
DN discharge port: : 11/2" to 21/2"
DN vent port: : DN 75
Mains supply : 1~230 V, 3~400 V, 50 Hz
P2 power : Up to 2 x 2.2 kW
Normal/Back-up configuration : 1 or 2 pumps
Regulation mode : Fixed speed
APPLICATIONS
Collection and lift-pumping of wastewater from collective residential, tertiary and commercial buildings.
BENEFITS
- Energy savings
Control by variation of level
- Easy installation
Compact product
Connection of inlets possible through 360°
Floor-mounted or buried installation is 100% tight to odours, gases and liquids
- Easy maintenance
Automatic operation
Easily removable pump
- System protection
Regulation of level by EAPS piezometric sensor
Integral motor protection via temperature sensor (NC - normally closed)
Corrosion-proof product
Sealing of motor by a single mechanical seal and lip seal
- Acoustic comfort
Quiet operation
DESIGN
- Motor
Synchronous technology motor, 304 or 316 L stainless steel casing, equipped with temperature
sensor in single-phase and three-phase versions
- Hydraulics
Polyurethane and cast-iron construction
Vortex, single-channel or grinding hydraulics
Double sealing with oil bath
- Tank
One-piece design made of corrosion-resistant HDPE: in 255 and 400 L
Integral check device, valve and suspension hook