LIFT-PUMPING MODULES COMPLIANT WITH EN 12050 - 1 / EN 12050 - 2 STANDARD

Collection and lift-pumping of wastewater from collective residential, tertiary and commercial buildings.

TECHNICAL SPECIFICATIONS

Flow rates of up to : 62 m³/h
Manometric head of up to: : 25 mWC
Fluid temperature limit : +35°C
Starting frequency : Recommended: 20/h
Maximum particle size : 10 to 44 mm
Effluent inlet : DN 100
DN discharge port: : 11/2" to 21/2"
DN vent port: : DN 75
Mains supply : 1~230 V, 3~400 V, 50 Hz
P2 power : Up to 2 x 2.2 kW
Normal/Back-up configuration : 1 or 2 pumps
Regulation mode : Fixed speed

APPLICATIONS

Collection and lift-pumping of wastewater from collective residential, tertiary and commercial buildings.

BENEFITS

  • Energy savings
    Control by variation of level
  • Easy installation
    Compact product
    Connection of inlets possible through 360°
    Floor-mounted or buried installation is 100% tight to odours, gases and liquids
  • Easy maintenance
    Automatic operation
    Easily removable pump
  • System protection
    Regulation of level by EAPS piezometric sensor
    Integral motor protection via temperature sensor (NC - normally closed)
    Corrosion-proof product
    Sealing of motor by a single mechanical seal and lip seal
  • Acoustic comfort
    Quiet operation

DESIGN

  • Motor
    Synchronous technology motor, 304 or 316 L stainless steel casing, equipped with temperature
    sensor in single-phase and three-phase versions
  • Hydraulics
    Polyurethane and cast-iron construction
    Vortex, single-channel or grinding hydraulics
    Double sealing with oil bath
  • Tank
    One-piece design made of corrosion-resistant HDPE: in 255 and 400 L
    Integral check device, valve and suspension hook

Documents

 

ACCESSORIES

  • “Alarmson” offset audible alarm box
  • Lip seals for additional inlets
  • Extension (maximum of 1)
  • Hand pump
selecson